Egcobox® MM10-K-BH /-BHS-V1-C30-H210-REI120-PS-C1
Technical Data
Egcobox® type |
MM10-K-BH /-BHS |
|
Shear force level |
V1 |
|
Connection height |
210 |
mm |
Joint width |
80 |
mm |
Concrete cover |
C30 |
mm |
Unit length |
500 |
mm |
Position number |
08-24-401 |
|
Wall / beam width bw: -BHS / -WUS |
175 ≤ bw < 220 |
mm |
Wall / beam width bw: -BH / -WU |
≥ 220 |
mm |
Negative moment resistance C2530 acc. to DIN EN 1992-1-1/NA |
-17,3 |
kNm/element |
Positive moment resistance C25/30 acc. to DIN EN 1992-1-1/NA |
0,0 |
kNm/element |
Positive shear force resistance C25/30 |
43,3 |
kN/element |
Compression bars |
- |
|
Length of compression bars from insulation |
- |
mm |
Compression bearings |
2 Ø 12 |
|
Tensile bars |
4 Ø 8 |
|
Length of tensile bars from insulation |
Depending on bending shape |
|
Length of tensile bars from insulation |
505 |
mm |
Banking faktor |
0,486 |
1/kNm/element |
Expansion joint distance |
11,70 |
m |
Fixed point distance loggia |
- |
m |
Total shear force bars |
2 Ø 8 |
|
Negative moment resistance C2530 acc. to EN 1992-1-1 |
-17,3 |
kNm/element |
Positive moment resistance C2530 acc. to EN 1992-1-1 |
0,0 |
kNm/element |
Storage unit |
Pce |
|
WG: |
260 |
|
Product download
Product-specific documents and tools are available for you to download, such as:
- Brochures
- Test certificates / approvals
- Technical data sheets
- Application guidelines / instruction of use
- FAQ
- Environmental declarations
- CAD Details
- Specification
- Safety data sheets
- Order forms
- Software