Egcobox® VM24-K-C35-H185-REI120-PS-C1
Technical Data
Egcobox® type |
VM24-K |
|
Shear force level |
- |
|
Connection height |
185 |
mm |
Joint width |
80 |
mm |
Min. wall / beam width |
180 |
mm |
Concrete cover |
C35 |
mm |
Unit length |
200 |
mm |
Position number |
08-24-750 |
|
Positive shear force resistance C25/30 |
24,3 |
kN/element |
Compression bars |
- |
|
Length of compression bars from insulation |
- |
mm |
Compression bearings |
1 Ø 12 |
|
Tensile bars |
- |
|
Length of tensile bars from insulation |
- |
mm |
Banking faktor |
- |
1/kNm/element |
Moment from eccentric connection Δ MEd (C2530) |
2 |
kNm/element |
Expansion joint distance |
11,70 |
m |
Fixed point distance loggia |
- |
m |
Total shear force bars |
2 Ø 6 |
|
Storage unit |
Pce |
|
WG: |
260 |
|
Description
Egcobox® type VM-K
- For supported slabs for the transmission of shear forces
- Insulation thickness: 80 mm
- Fire resistance rating depending on variant R0, REI 120
Product download
Product-specific documents and tools are available for you to download, such as:
- Brochures
- Test certificates / approvals
- Technical data sheets
- Application guidelines / instruction of use
- FAQ
- Environmental declarations
- CAD Details
- Specification
- Safety data sheets
- Order forms
- Software