Egcopal SPH O ± for in-situ construction, joint width 81 - 100 mm
Technical Data
Type |
SPH O± |
|
Application |
In-situ concrete |
|
Execution |
High load |
|
Direction of load |
Top bottom |
|
Product load-bearing capacity VRd,s |
37,3 |
kN/element |
Heat transition coefficient |
0,125 |
W/K |
Joint width |
81 - 100 |
mm |
Dowel length |
420 |
mm |
Slab height |
≥ 160 |
mm |
Weight |
11,310 |
kg/pce |
Storage unit |
Pce |
|
WG: |
279 |
|
Dowel diameter |
52 |
mm |
Description
Egcopal SPH impact sound insulated shear force dowel for in-situ concrete
- Shear force connection (consisting of mandrel part and acoustic box) separates the components from each other in terms of sound and heat, for example in arcades
- Landing impact sound pressure level difference ∆L*w, landing 30 to 31 dB
- Mandrel diameter Ø = 52 mm
- Heat transfer coefficient 0.125 [W/K]
- Fire resistance class F120 for joint width up to 70 mm
- Product load-bearing capacity VRd 37,3 [kN/element]
- From panel thicknesses ≥ 160 mm
- National technical approval by the DIBt